|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Contact Factory for Replacement Model Input Specifications Parameter Operating Range Inrush Current Limiting 36VDC 72VDC Efficiency 48VDC at full load 70 25 50 APK APK % Conditions DC Min 36 Typ 48 Max 72 Units VDC Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off (Optional) The power supply is turned on with a TTL logic `1' (or open) signal and turned off by a switch closure or TTL logic `0' referenced to (-) sense terminal. Over Voltage Protection Output #1: 6.5V 0.5 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Active Inrush Current Limiting Inrush current is independent of ambient temperature. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 sec for a 25% load step change. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety Safety Certified to UL/CUL to 1950, File Number E131694. TUV to EN60950/IEC 950. Cooling The unit is designed to operate with 30 CFM of airflow. Page 2 DNX350 4/2002 REV B Output Voltages and Maximum Rated Loads OUTPUT #1 VOUT IMAX +5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 12V 15V 12V 12V 12V 15V 15V 15V 15V 10A/12A 10A/12A 10A/12A 10A/12A 10A/12A 10A/12A 10A/12A 10A/12A 10A/12A 12V 15V 12V 12V 12V 15V 15V 15V 15V 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 8A/10A 5V 24V 12V 5V 24V 12V 12V 3.0A 1.5A 3.0A 3.0A 1.5A 3.0A 3.0A MODEL NUMBER DNX350-U1A DNX350-U3A DNX350-U3B DNX350-U4C DNX350-U4D DNX350-U4E DNX350-U4F DNX350-U4G DNX350-U4H DNX350-U4I OUTPUT #2 VNOM IMAX/IPK OUTPUT #3 VNOM IMAX/IPK OUTPUT #4 VNOM IMAX/IPK Output Specifications Parameter Regulation Line Load Cross Minimum Load Output #1 Auxiliary Outputs 3.0A 0.1A 0.03% 0.25% 0.05% Limits Parameter Voltage Adustment Range PARD Temperature Operating Storage Temperature Coefficient (TC) Conditions Nominal line on all outputs Peak-to-peak 20 MHz bandwidth Min Typ 5 Max 1 Units % % P-P 0 -20 After half hour warm-up 0.02 50 +70 C C %/C DNX350 4/2002 REV B Page 3 Mechanical TOP MOUNTED FAN 1 TB1 PLUS 6.94 3.34 NO. 1 +V OUTPUTS NO. 1 -V FAN OPTION 1 2 3 AIR FLOW MINUS OUTPUT OUTPUT 4 3 ADJ. ADJ. OUTPUT 5 ADJ. 1 4.85 3.60 3.90 0.62 0.55 0.25 1 TB2 6-32 MOUNTING LOCATED ON BOTTOM (4x) 8.50 9.00 1.99 3.00 END MOUNTED FAN 0.250 8.50 2.15 0.550 J10 TB2 3.900 AIR FLOW 4.850 J9 3 2 1 1.00 9.00 6-32 THD 4 PLC'S OUTPUT NO. 1 RETURN 10-32 STUD OUTPUT NO. 1 10-32 STUD NOTES: All measurements are in inches COOLING: The DNX350 is designed to operate with 30 CM airflow. SHOCK AND VIBRATION: The DNX350 meets the requirements of MIL STD-810D. WEIGHT: Approximately 3 lbs. 1 Terminal Block 1 POS 1 2 3 FUNCTION DC + DC Ground Terminal Block 2 POS 1 2 3 4 5 6 FUNCTION -V2 +V2 -V3 +V3 -V4 +V4 PIN 1 2 3 4 5 6 7 8 9 J9 Connector Molex No. 22-28-1090 FUNCTION + Sense - Sense N/C N/C Start Up Sync. N/C Remote Inhibit Current Share Control Signal Rtn POS 1 2 3 J10 Connector* AMP 1-480701-1 FUNCTION DC+ DCGROUND *Used with end-mounted fan cover, option "V" Page 4 DNX350 4/2002 REV B |
Price & Availability of TPSDNX350 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |